Construct a portable building on skids that has a 3/8’ minimum thickness of antiwear plate on all ground contact points. All ground contact joints need to be capped or covered. The minimum interior base dimensions need to be 32’x34’with an interior high eve minimum of 19’ and interior low eve minimum height of 17’. There will be 3 white doors on the high eve wall. The first door being a minimum width of 14’ with a minimum height of 15.5’ and will be a manually operated sectional door that is stowed next to the wall. The center of this door will be 9’ from the interior wall. The second door will be a white standard steel 36” walk in door stationed between the 2 sectional doors and can be located up to 14” off the bottom of the building. The third door will be a minimum width of 11’ and a minimum height of 12.5’ also a manually operated sectional door that is stowed next to the wall. The center of this door will be 7’ from wall. The wall opposing the 19’x34’ wall will be 17’x34’. This building will be of all steel construction:, 26 gauge or thicker steel siding and roofing will be used. To tow the building a Cat 963 track loader or a Cat 938 loader will be used, the attaching equipment will need to be supplied. This building will need tow points on the low and high-eve wall. This building will need tie off points and a method of tying down the building quickly by moving weights with a loader, and supplied with the building, if the building weight does not meet building wind standards of 105 mph minimum. This building can use drop in and bolt down hardware in the sectional door frames as needed, a permanent support can be run from the area below to the side of the man door to the back of the building. A permanent support can be installed 4’ from the center of the building closest to the 17’x34’ wall. When this building is moved the surface will be bladed prior to moving and the placement. This building will not have more than a 1” gap to seal to the ground. An electrical panel that can be plugged into a 50-amp 240volt plug outlet with a 20ft minimum drop cord on site to provide power to 3 120volt 20-amp outlets and 4 interior led lights (20,000 lumen minimum total) on a single switch. This building can have a hinged joint up to 12” at the bottom of the building on the low and high-eve walls. This building will need to be able to be moved by 2 technicians in 4 hours or less, with the assistance of the 963 Cat tracked loader, or the 938k Cat loader with forks and the use of hand tools and impact wrenches. This building does not have any insulation. This building will need to be able to handle snow loads of 30 lbs. per sq ft. This building will need to be BC Steel Light Stone and Fern Green trim, or a near color match to the Douglas Transfer Station. This building will be moved around the Douglas Landfill for 25 plus years. Expected warranty on the building is 1 year minimum.