Specifications include, but are not limited to: In general the work consists of replacing the obsolete theatrical dimming system and associated lighting outlets and wiring. Project work includes three components: (1) Replacing network switching equipment, (2) Replacing surface-mounted outlet boxes, and (3) Replacing dimming racks. Network switching and dimming equipment in the performance space will be replaced with two new networks for better house control. New connection panels and interface equipment will also be installed, including a stage manager panel for DMX gateway, LCD control station, symphony lighting controls, and dedicated emergency/panic stations. A new control rack will replace the existing rack. Supply control receptacle panels will include booth control, house mix control, and three separate stage controls. Thirteen new control receptacle panels are included. Ninety-five (95) surface-mounted outlet boxes with varying pin connectors and other Edison type duplex outlets, outlet panels for the spot booth, as well as 50-foot multi-cable extensions, will be replaced. The house dimming equipment will be replaced with five new dimmer racks and dimmer modules with vibration mounts, two echo relay panels with main breakers, and required equipment.