Specifications include, but are not limited to: Remove protops/flushmount cover units and bumper posts on all 21 wells. No wells are located in paved areas. Abandon each of three monitoring wells (OW‐301B, P‐301C, OW‐319A) after removing the protective well cover by cutting the PVC riser off a minimum of 30” below grade and gravity filling riser with 3/8” bentonite chips. Abandon eighteen remaining monitoring wells per NR 141. 25 (2)(c) to include removal of protops, PVC well casing and screen material for each well. Per NR 141.25(2)(d) wells will be abandoned from the bottom up with grout as described in NR 141.25(2)(d) as the PVC is removed or after over‐drilling. Remove all waste material from each well location, including soil and bentonite drill cuttings, PVC, steel, etc and place in a roll off box provided by County. At offsite well locations P‐106B, OW‐301B and P‐301C repair surface of borehole to blend with surrounding area (sod and gravel respectively).