Specifications include, but are not limited to: Bids shall cover: Routing of defective mortar joints and repoint with Type N mortar including used anchor holes. Perimeter joints of all window to wood surfaces to include; preparation of the surface, installation of back rod if necessary and application of Tremco Dymonic 100 polyurethane sealant (color to be determined). Perimeter joints of all wood to masonry surfaces to include; preparation of the surface, installation of back rod if necessary and application of Tremco Dymonic 100 polyurethane sealant (color to be determined). Product to be installed within manufacturer specifications. The manufacturer may perform pre‐installation and random pull tests. Reference document titled Testing.