Specifications include, but are not limited to: 3.1.1.1 Outer dimension for freezer box size must be a minimum 7’ 9” to a maximum 8’ 3” wide, a minimum of 9’ 9” to a maximum of 10’ 3” deep, must be a minimum height of 8’ to 8’ 7” maximum height. 3.1.1.2 Entrance door must be a minimum of 36” wide and a minimum 78” high to be located center of front 8’ wall. 3.1.1.3 Unit must include an entry ramp that will be a minimum 38” to a maximum 42” wide and a minimum 26” to a maximum 30” long. Ramp must slope from ground level to meet with floor of unit. 3.1.1.4 Unit must have a split unit for freezing with 50’ line set. 3.1.1.5 Power shall be as follows: 3.1.1.5.1 Cooling unit must be 208 volt single phase 3.1.1.5.2 Condensing unit must be 208 volt three phase. 3.1.1.6 Unit must include one (1) 4’ cooler light fixture. 3.1.1.7 Must have switch with pilot light located on outside of unit at entrance door. 3.1.1.8 Door must have heater, magnetic gasket, and handle with inside release. 3.1.1.9 Unit must include door closer. 3.1.1.10 Unit must include defrost timer. 3.1.1.11 Unit must include digital thermometer