Specifications include, but are not limited to: 1 – Reconditioned Ashbrook Type 85 Klampress, 2 Meter Belt Press Heavy Duty, Hot Dipped galvanized Frame Heavy Duty Split case Roller Bearings and 8 “S” Wrapped Rolls Hydraulic Tracking and Tension Reconditioned NEMA 4X Control Panel - including new press, pump, and conveyor controls New venture mixing valve with 4 point injection ring New set of belt fabric Reconditioned hydraulic Unit Complete inspection of Press All bearings must be inspected. Any bad or questionable bearings must be replaced Control panel must include new starter relays, VFD drives and push buttons. Hydraulic power unit must be reconditioned including, changing of the hydraulic oil and filters. Inspection of tracking valves. Rebuild or replace as needed. Inspect wiring on press including new limit switches for belt misalignment and emergency stops. Perform plumbing work required for filtrate drains. Install new rubber seals for gravity, wedge and shower boxes. Install new belt fabric.