Building Type Pre-Engineered Metal Building (PEMB) Use Law enforcement training support facility; storage + instruction shelter Overall Size 40’-0” (width) x 60’-0” (length) Eave Height 10’-0” Roof Pitch 3:12 to 4:12 (acceptable range) Roof Type Galvalume standing seam or equivalent Wall Panels 26-gauge (Galvanized) steel, color-coated (color to be selected by county personnel) Gutters & Downspouts Continuous gutters with downspouts on both sides to manage roof runoff; color to match wall exterior. Minimum 26 gauge steel or Aluminum Frame Type I-Beam rigid frame- ASTM A36 or A992 (preferred) Wind Load Per latest IBC & Virginia Building Code Snow Load Per latest IBC & Virginia Building Code Seismic Zone As applicable to Stafford County, VA Code Compliance Virginia USBC (latest edition), IBC Warranty Minimum: 25-year painting, and overall building warranty 1 year