0001
FLUKE T5-1000
ELECTRICAL TESTER KIT WITH HOLSTER AND 1AC II VOLTAGE TESTER
MODEL#: FLUKE T5-H5-1AC II KIT
REF P/N 2PY98
100
EA
Determined by vendors
Determined by vendors
T5-600/T5-1000
Electrical Tester
Parts and Service
The tester is warranted to be free from defects in material and workmanship for two years, while under normal use. Parts and repairs are warranted for 90 days. For the complete warranty statement, refer to the
TS-600/TS-1000 Electrical Tester Instruction Sheet.
To order parts, or for warranty service, contact Fluke as follows: USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (l-800-363-5853) Europe: +31402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com.
Specifications
Accuracy is specified for one year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows:
::!;([ % of reading] + [number of least significant digits])
Temperature coefficient of 0.1 x (specified accuracy)/ °C for <18 °C or >28 °C (<64.4 °For >82.4 °F)
Serial Numbers 79560000 and Above
General Specifications
Calibration
One-year calibration cycle.
Maximum Voltage
Between any Terminal and Earth Ground
TS-600: 600 V rms, Overvoltage Category Ill, Pollution Degree 2
TS-1000: 1000 V rms, Overvoltage Category Ill, 600 V RMS, OverVoltage Category IV, Pollution Degree 2
Maximum Voltage
Between Current Fork and Earth Ground
TS-600 and T5-1000: 1000 V rms, Overvoltage Catergory Ill, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.)
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)
Relative Humidity
O o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); o o/o to 75 %, 30 °C to 40 °C (86 °F to 104 °F);
O o/o to 45 %, 40 °C to 50 °C (104 °F to 122 °F)
Battery Type and Life
AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride
Shock, Vibration
1 m drop at -10 °C to + 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-1
1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)
Surge Protection
TS-600: 6 kV per IEC 61010, T5-1000: 8 kV per IEC 61010
Enclosure Rating
IP 52 per IEC 60529, no vacuum applied
General Specifications (continued)
RF Field Specification
0.5 % full scale + (specified accuracy) at 3 V/m
Safety
Complies with ANSI/ISA-S82.0l-94, UL Classified to IEC 61010, CSA/CAN C22.2 No.1010.1- 92, and EN61010-11995.
EMC
EN 61326
Certifications
CE <ti® ��S®IF,� C
In accordance with IEC 61010-1 54CJ
Resolution and Accuracy
Function
TS-600 Range
TS-1000 Range
Resolution
Accuracy
v
600 V rms
1000 V rms
lV
:!(1.5 % + 2 digits)
v
600V
1000V
lV
:!(1% + 1 digit)
~A
100.0A
100.0A
0.lA
:!(3 % + 3 digits)
n
10000
1000 0
10
:!(1o/o + 2 digits)
Input Characteristics
Function
Input Protection
Input impedance (nomial
T5-600
TS-1000
v
600 V rms
1000 V rms
1 MO, <100 pF ac-coupled
v
600 V rms
1000 V rms
1 MO, <100 pF
n
600 V rms
1000 V rms
n
Open Circuit Test Voltage
Short Circuit Current
1.65 V de (nominal)
<600 µA
CAT Ill protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.
CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.
Serial Numbers 79559999 and Below
General Specifications
Calibration
One-year calibration cycle.
Maximum Voltage Between any Terminal
and Earth Ground
TS-600: 600 V rms, Overvoltage Category Ill TS-1000: 1000 V rms, Overvoltage Category Ill
Temperature
Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft)
Relative Humidity
0 o/o to 95 %, 5 °C to 30 °C (41 °F to 86°F); 0 o/o to 75 %, 30 °C to 40 °c (86 °F to 104 °F);
0 o/o to 45 %, 40 °c to 50 °C (104 °F to 122 °F)
Battery Type and Life
AA (2); 400 hours continuous with alkaline; 200 hours continuous with zinc chloride
T5-600/T5-1000
Electrical Tester
General Specifications (continued)
Shock, Vibration
1 m drop at 15 °C to 35 °c (59 °F to 95 °F) per ANSI/ISA-S82.0l-1994 and EN 61010-11993.
Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum)
Surge Protection
T5-600: 6 kV per IEC 1010-1, 1990-09: T5-1000: 8 kV per IEC 1010-1, 1990-09
Enclosure Rating
IP 52 per IEC 60529, no vacuum applied
RF Field Specification
0.5 % full scale + (specified accuracy) at 3 V/m
Safety
Complies with ANSI/ISA-S82.0l-94 for use in overvoltage category Ill (CAT Ill) locations, UL3111, CSA/CAN C22.2 No.1010.1-92, and EN61010-l 1993.
EMC
EN 50081-1, EN 50082-1
Certifications
( E c@us ct ®®
Resolution and Accuracy
Function
TS-600 Range
TS-1000 Range
Resolution
Accuracy
v
600 V rms
1000 V rms
lV
:!(1.5 % + 2 digits)
v
600V
1000V
lV
:!(1% + 1 digit)
A
100.0A
100.0A
0.lA
:!(3 % + 3 digits)
n
10000
10000
10
:!(1% + 2 digits)
Input Characteristics
Function
Input Protection
Input impedance (nomial
T5-600
T5-1000
v
600 V rms
1000 V rms
1 MO, <100 pF ac-coupled
v
600 V rms
1000 V rms
1 MO, <100 pF
n
600 V rms
1000 V rms
n
Open Circuit Test Voltage
Short Circuit Current
2.4 V de (nominal)
<600 µA
CAT 111 protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings.
CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service.
Cleaning the Tester
�Warning
To avoid electric shock or damage to the tester, never allow water inside the case. To avoid damaging the tester's case, never use solvents on the tester.
If the tester requires cleaning, wipe it down with a cloth that is lightly dampened with water or a mild detergent. Do not use aromatic hydrocarbons, chlorinated solvents, or methanol-based fluids when wiping down the tester.
The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 334515, Electrical and Electronic Properties Measuring and Testing Instruments, with a size standard of 750 employees. The Product Service Code is 6625. The solicitation document incorporates provisions and clauses in effect through FAC 2025-04 and DFARS Change Notice 01/17/2025.
The anticipated delivery date for this acquisition is 6 weeks after receipt of contract. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only.
The solicitation number is SPMYM125Q0137, and it is expected to be available on or about
07 AUG 2025 and posted to SAM.gov, https://sam.gov/ Quotes will be due by 12:00 PM EST on 13 AUG 2025. Responses to the solicitation notice shall be emailed to the attention of Curtis Douglas at Curtis.douglas@dla.mil . Please make sure that the solicitation number
(SPMYM125Q0137) is included in the subject line of any email correspondence. Emails
without subject lines will not be read because of security issues.
Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for the inability of the Offeror's to access solicitation documents posted. Prospective Offeror's should also register on the interested vendor list under SPMYM125Q0137. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.
All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the
solicitation, except for awards to foreign vendors for work to be performed outside the United
States. Lack of registration in the SAM database will make an offeror ineligible for award.
Offerors may obtain information on registration and annual confirmation requirements by calling
1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in
accordance with the solicitation, dates and procedures. Please direct all questions regarding this
requirement to Curtis Douglas at Curtis.douglas@dla.mil