Specifications include, but are not limited to: Supply and Install two (2) 195’ monopole towers in Mathews County Diameter: 68.580 in (flat to flat) Thickness: 0.5625 in Yield (Fy): 65 ksi # of Sides: 18 "0" IF Round Strength (Fu): 80 ksi Anchor Rod Results (per 4.9.9) Moment, Mu: 10618.74 ft-kips Rigid Axial, Pu: 86.61 kips Maximum Put: 195.34 Kips AISC LRFD Shear, Vu: 68.52 kips t*Rnt: 243.75 Kips Other Vu: 2.02 Kips v*Rnv: 149.10 Kips Tension Interaction Ratio: 0.64 Quantity: 34 Maximum Puc: 199.80 Kips Diameter: 2.25 in c*Rnc: 268.39 Kips Rod Material: A615 Vu: 2.02 Kips Strength (Fu): 100 ksi c*Rnvc: 120.77 Kips Yield (Fy): 75 ksi Compression Interaction Ratio: 0.74 BC Diam. (in): 76 BC Override: Maximum Interaction Ratio: 74.5% Base Plate Results Diameter (in): 81.75 Dia. Override: Rigid Thickness: 2.75 in Base Plate (Mu/Z): 38.3 ksi AISC LRFD Yield (Fy): 50 ksi Allowable *Fy: 45.0 ksi (per AISC) Eff Width/Rod: 6.40 in Base Plate Interaction Ratio: 85.1% Drain Hole: 2.625 in. diameter Drain Location: 32 in. center of pole to center of drain hole Center Hole: 56 in. diameter Reactions 511621 Bohannon, VA Round Base Plate and Anchor Rods, per ANSI/TIA 222-H