Specifications include, but are not limited to: 2.1 Fire Station 2A.Demo existing access controls panel. B.Provide and install (1) SEC-ENC3042WDP enclosure, (1) power supply and 2 backup batteries with DIN rails for modules and controller. C.Provide and install (5) S300-DIN-RDR2SA to enclosure. D.Move (1) existing CK721A controller to new panel. E.Move (1) existing RDR2SA module to new panel. F.Provide and install 1 new (AL600ULACM) and 2 (S300-BAT) batteries. G.Install (3) sets of access controls to include the following doors (The set will include Electric Strikes, Rex, Readers (920NTNNEK00000) and DPS): 1.The Operational Office2.The President’s Office3.Chief’s Office. H.The data closet is located across from the Operational Office. I.Utilize existing wiring, card readers, REX motion detectors, door contacts and locking hardware. All deficiencies found to existing doors and hardware during upgrade to be quoted as separate repairs. J.Utilize existing 120VAC power connections provided by Stafford County. K.Stafford County will provide static IP addresses, port designations, and network connectivity support for upgraded card access equipment. L.Provide programming of the new readers being installed. M.Test and train on new and relocated readers. 2.2 Fire Station 9A.Provide and install (1) SPA1B200-1B10 P2000 access control panel, (1) power supply, and (4) Backup batteries in the data room. B.Install (1) set of access controls to include the following doors (The set will include Electric Strikes, Rex, Readers (920NTNNEK00000) and DPS): 1.Front DoorC.Join access controls into P2000 system located in the PSB in main County complex. Stafford County will provide IP addresses and network connection to the PSB building. Stafford County will have the access control panel connected to the existing data network racks (supplied by Stafford County) located in the data closet on the 3rd floor. D.Stafford County will provide static IP addresses, port designations, and network connectivity support for new card access equipment. E.Provide programming of the new readers being installed. Test and train on new and relocated readers.2.3 Fire Station 10A.Provide and install (1) SPA1B200-1B10 P2000 access control panel, (1) power supply and 4 backup batteries. B.Provide and install (2) 920NTNNEK00000 –R40 card readers, (3) REX, (3) DPS, and (2) Electric Strikes (1006CS-12/24D-630) to the following doors: 1.Front Entrance door: We will re-use the electric strike already installed on doors. (Assumes the doors and electric strikes are in good working order. In the case, the strike is in need of repair, issue a change order for a replacement). Provide and install (1) 900NTNNEK00000 Mullion R10 card reader, replace DPS, and replace REX. 2.Upstairs Back door to meeting room: provide and install (1) 2280 1200 lb. Magnetic lockset to the left door. The right door will stay dog eared locked in place. Provide and install 1 exit button, 1 REX, and (1) DPS.3.Outside road facing outer door to Fire Marshal vehicle bay. C.Utilize existing 120VAC power connections provided by Stafford County. D.Join access controls into P2000 system located in the PSB in main County complex. Stafford County will provide IP addresses and network connection to the PSB building. Stafford County will have the access control panel connected to the existing data network racks (supplied by Stafford County) located in the data closet on the 3rd floor. E.Stafford County will provide static IP addresses, port designations, and network connectivity support for new card access equipment. F.Provide programming of the new readers being installed. Test and train on new and relocated readers.