Specifications include, but are not limited to: 20 @ SCBA Assembly plus mask, NFPA 1981 Standard on Open Circuit Self-Contained Breathing Apparatus 2018 edition, with padded and reflective harness/ lumbar support, with integrated PASS device compliant with NFPA 1983, with all hoses interior to the pack, and push-to-connect or quarter turn Demand Valve, Quick-Connect Cylinder connections, + plus Masks – NFPA 1981 Standard on Open Circuit Self-Contained Breathing Apparatus 2018 edition, with nose cups, HUD that is field removable, with voice amplifier. Masks to be fitted and tested to FD members. The Assembly/ mask should be as demonstrated at Bethel Fire Department. 40 @ Composite Cylinders, 4500 psi/ 45 minute with Quick Connect adaptors. 6 @ Masks, additional – NFPA 1981 Standard on Open Circuit Self-Contained Breathing Apparatus 2018 edition, with nose cups, HUD that is field removable, with voice amplifier, and push-to-connect or quarter-turn Demand Valve. Same as masks included in the Assembly package above in item #1. Masks to be fitted and tested to FD members. As demonstrated at Bethel Fire Department. Line Item Add-On’s to be bid by line item priced per each and total price per line item. 2 –@ Spectacle kit 2 @ Charging Adaptor HP for compressor for Quick Connect 2 @ Carrying cases hard or soft 1 @ Battery charger if required for system batteries that are rechargeable 5 @ Buddy Breather/ Universal Air Connection add on, installed Equipment to be set up and all masks fitted to fire personnel at delivery or within a reasonable amount of time but less than 2 weeks from delivery.