Specifications include, but are not limited to: Construct a 175 foot self supporting tower per TxDOT tower specification and this site information sheet at location listed on this site information sheet. The vendor is responsbile for ALL enviromental studies, permits, NEPA, EPA, SHP, tribal clearances, building, or regulatory permits. Vendor is responsible for ALL connections, adding of power drops and associated needs to provide electrical power to the site. The upper 40 feet of the tower will be straight with no taper. All antennas mounted on the tower are to use Commscope MTC3356 anti torgue antenna brackets. NO use of any other type of antenna mounting clamp or method is allowed unless approved by TxDOT in advance. All antennas mounted on tower legs are to use 48 inch stand off brackets. An equipment shelter is to be provided and installed as noted per the TxDOT tower specification and in next section. Precise placement of tower to be determined at Pre-Construction meeting on site. All other configurations per TxDOT communications site specification, site information sheet and attached referance documents