Specifications include, but are not limited to: . Remove all existing fencing as required where fencing is shown to be replaced in same location. Removal shall include all posts and existing post bases including concrete. Infill existing post base holes with compacted fill where not to be reused. ; Chain Link Fabric • Spectra Bond by Master Halco (or equal) 2" x 9-gauge core (6 gauge finish) • Spectra polyvinyl chloride extruded and adhered to zinc-coated steel (Color: Black) • Meets ASTM F668, Class 2A • 12 year limited warranty Fence Pipe & Railings • Pipe-Spectra polyester resin, 3 mils minimum, over galvanized steel (Color: Black) • ASTM F 1043, group 1 C with a minimum yield strength of 50,000 PSI • 12 year limited warranty • Line posts will be 2 3/8" DQ-40 • Terminal posts will be 2 7 /8" DQ-40 ; Installation Requirements • Post spacing for line posts shall be 10’-0”oc, max. • Post holes will be 12" in diameter • Post holes will be 3' deep • Holes for gate posts will be 4' deep • Any straight run over 500' will have terminal posts in the middle of the run • All fence shall receive bottom wire attached to posts at base of fence (Color: Black) • All sliding gate frames shall be constructed of welded components • Provide support wheels on sliding gates over 6’-0” wide per leaf .