Specifications include, but are not limited to: Metal Storage Building • Dimensions o Width: 40 feet o Length: 60 feet o Peak Offset: 20 feet o Sidewall Bay Space: 3 @ 20 feet • Eave Hight o Front: 12 feet o Back: 12 feet • Roof Slope o 2 in 12 • Girt Type o Flush • Frame Type: Rigid • Rafter Type: Tapered • Building Code: IBC ‘18 • Building Loads o Dead Load: 2.50 PSF o Live Load: 20 PSF o Load Reduction: Yes o Ground Snow: 5.0 PSF o Collateral: 4.0 PSF o Wind Load: 107 MPH • Frame Coating o Main Columns & Rafters: Red Oxide o Purlins, Girts, Eave Struts: Red Oxide o Door Framing: Red Oxide o Base Angle: Red Oxide • End Frames o CF Endwall: Left and Right • Wall Bracing o Roof: Diagonal Bracing o Left Endwall: Panel Shear o Front Sidewall: Other o Right Endwall: Panel Shear o Back Sidewall: Other • Framed Openings o Left Endwall o Bay: 2 o Open Width: 14 feet o Header Height: 10 feet o Sill Height: 0 o Offset: 0 • Sheets & Trim o Roof Gauge: 26 o Walls Gauge: 26