Specifications include, but are not limited to: upgrade the existing jail control system using new software and a new PLC controller but leaving the relay hardware in place since its still available on the market today.; 1. Upgrade the Omron system to include a new software loaded onto a server provided by City of Denton. ; 1. Basis of Design is the Omron Indusoft V2020 or the Omron Aveva Edge V2020. ; 2. Load a client software onto the local PC to be housed inside the control room. ; 3. Load a client software onto the local PC to be housed inside the booking counter. ; 4. Provide an override feature that can lock the booking counter station in the event its immediate surrounding is compromised. ; 5. Extract all possible data from the existing system to work as a platform to the upgrade. ; 6. Ensure that all lock and latch monitoring sensors are identified as working or in need of repair. These in need of repair shall be notified in writing to the owner as soon as noticed. ; 7. The upgraded software shall function the same as the existing software and be mouse controlled.: 1. Detention door locked ; 2. Detention door position ; 3. Intercom icon for selection ‐ when selected it auto listens and has Push to Talk (PTT) feature ; 4. Camera streams are not automated but instead are displayed on wall mounted monitors and not part of this scope. ; 5. Doors opening counts are not a desired feature. ; 8. Provide an updated floor plan showing the new sally port doors, outer sally port doors, and jail lobby configurations. ; 9. Add one relay input for connection to the building access control that only controls jail lobby door. ; 10. Provide a complete turnkey system using existing hardware and providing new software, software loads, and software configuration. ; 1. Basis of Design includes: 1. Replace obsolete CJ1G‐CPU **PLC CPU with equivalent CJ2**CPU; 2. Replace PLC Power Supply with a new Omron CJ series