Installation, maintenance, and record keeping of a Storm Water Pollution Prevention Plan (SWPPP) for the seven (7) sites with stand-by generators, complete as specified for the sum of: 1 LS 9 Construction of Lehman Booster Pump Station Generator which includes but is not limited to the construction of a minimum 125kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 10 Construction of Yarrington Booster Pump Station Generator which includes but is not limited to the construction of a minimum 175kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 11 Construction of Well No. 3 and Booster Pump Station Generator which includes but is not limited to the construction of a minimum 250kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, service rack canopy, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 12 Construction of Well Nos. 1 & 5 and Booster Pump Station Generator which includes but is not limited to the construction of a minimum 450kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 13 Construction of Well No. 2 Generator which includes but is not limited to the demolition of the existing single-phase service and associated electrical; construction of a minimum 150kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, service rack canopy, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 14 Construction of Masonwood Lift Station Generator which includes but is not limited to the demolition of existing chain link fence; construction of a minimum 50kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, chain link fence, swing out gate, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 15 Construction of Kensington Trails Lift Station Generator which includes but is not limited to the demolition of existing chain link fence, swing out gate and asphalt pavement; construction of a minimum 50kW diesel generator with a sub-base fuel tank, sound attenuated enclosure, automatic transfer switch, chain link fence, swing out gate, concrete pavement, miscellaneous electrical, duct bank, conduit, wire, slab and all else as shown on the construction drawings and detailed in the specifications, complete in place for the sum of: 1 LS 16 The Work at Well No. 4 site consists of providing the necessary labor, materials, equipment, and supervision to purchase, factory test, and deliver one (1) mobile generators to City of Kyle Well No. 4 facility including but not limited to, bonds and insurance; Minimum 500-kW diesel engine driven trailer mounted generator with sound attenuated weatherproof enclosure and 24-hour storage tank, and all else detailed in the specifications. 1 LS