Specifications include, but are not limited to: furnish, install, and program access control. This includes card readers, electrified locksets, door position sensors, gate releases, control panels, intercoms, access control cabling, gate operators, surge protection, card reader pedestals and CCTV. The system must be compatible and interoperable with TXDOT’ latest version Software House CCURE as a standard. Furnish and provide a utility scan at each site. Refer to the specification requirements. Work of the projects also includes demoltion of existing chain link fencing as indicated on the drawings. Clear trees, bushes and vines as indicated on the drawings, two feet of each side of fence line where fence line is on TXDOT property. Where fence line borders another property line/fence line clearing to be coordinated with TXDOT project manager. Minimum of 2 foot clearing on TXDOT side. Stump grinding of trees, bushes and vines. Comply with local, state and federal ordinances and laws. Furnish and install 9 ga, 6ft chain link fence with top rail and 3 strand barbed wire and or associated components as indicated on the drawings. Furnish and install MaxStop fence as indicated on the drawings. Furnish and install cantilever gates, gate operators with safeties, safety loops and associated safety devices to comply with UL 325 standards as indicated on the drawings.