Specifications include, but are not limited to: a) Except as noted on the plans or procurement specifications for specific jobs, all C900 PVC pipe shall be Class 150 (DR 18) having a sustained pressure requirement of 500 psi (ASTM D2241) and a minimum burst pressure of 755 psi (ASTM D1599). C900 PVC pipe installed in the SAWS High Pressure Zone shall be class 200 (DR 14) having a sustained pressure requirement of 650 psi (ASTM D1598) and a minimum burst pressure of 985 psi (ASTM D1599). b) Dimensions and tolerances for each nominal pipe sizes shall be in accordance with Section 2.2, Table 1 of AWWA Standard C900. c) Pipe shall be furnished in standard laying lengths of 20 feet (plus or minus one inch) unless otherwise noted. Each pipe shall have an integral bell formed on the pipe end, and be designed to be at least as strong as the pipe wall (ASTM D2472).