Specifications include, but are not limited to: WB-458 Horizontal Water Bath Propane Vaporizer Specifications: Vaporizer Capacity: 458 gallons/h (42.1 MMBTU/h) of LPG Water Capcity: 165 gallon (0.625 m3) to Fill Plug Design Temperature: 650 degrees F (343 degrees C) (Vapor Tube) Design Pressure: 250 psig (17.2 bar) (Vapor Tube) Test Pressure: 375 psig (25.9 bar) (Vapor Tube) Manufactured Construction: Vaporizing Tube Conforms to ASME Boiler & Pressure Vessel Code Section VIII, Division 1. Conform to lastest edition of NFPA #58 Standard Safety Features: Ignition Failure Safety Shut Down; Low Water Level Cutoff; High Water Bath Temperature Cutoff; “Smart” Liquid Carryover Protection; Pressure Relief Valve Protection (Vapor Tube); Pressure Relief Valve Protection (Burner Train); Low Burner Fuel Gass Pressure, High Burner Fuel Gas Pressure; Gas Leak Monitor with Infrared sensor; Dual Emergency Stop circuits; Agency-approved Safety System for burner protection, gas leak monitoring, and ESD loops for Performance Level 4 (formely SIL-3) Burner Type: Forced Draft Power Burner with Electric Blower