Specifications include, but are not limited to: The height of the panels separating the customer service stations must be 65 inches. The height of the panels for other cubicles marked SET and PC must be 42 inches with an additional 24 inches of glass. (shown on the conceptual plan) The height of the panels for other cubicles shown on the plan must be 42 inches. ; The standard wall is assumed to be 5/8" gypsum wallboard (GWB) on metal studding, spacing as recommended by manufacturer of metal studding ; Tenant Entry Doors: Landlord must provide and install 1 3/4" thick x 3'-0" wide x 6'-8" to 7'-0" high, 16-gauge metal or solid core wood doors with hardwood stain grade veneer in 16-gauge welded steel frames. ; For new installation, Landlord must provide and install an acoustical tile ceiling system consisting of 2' x 2' x 5/8" or 2' x 4' x 5/8" lay-in panels in a lay-in suspension system.