Specifications include, but are not limited to: Kit Item Descriptions for HVAC Overhaul Kit PIN LRV-H1 Compressor Assembly - Assembly A, • Includes: two compressors, cradle, all piping around compressors, vibration mounts, suction and discharge vibrasorbers, sight glass, pressure relief valve and mounting hardware. Plug and Play. Condenser Fans and Motor Assembly - Assembly B, • Includes: two condenser motors and two condenser fans Evaporator Blower Assembly - Assembly C, • Includes: evaporator motor, left and right blower wheels, and housing • Assembled and balanced ready to install. CONTRACT NO. Control Box Assembly - Assembly D, • Includes: All contactors, circuit breakers, relays, bus bars, temperature sensors, wires and pre harnesses. • Also includes an up to date microprocessor controller in the fully assembled control box. • This will be a fully assembled control box. • Full plug and play. • Worry free and fully compatible with both newer Houston II and Houston III Heating Bank Assembly - Assembly E, • Includes fully assembled heating bank and three temperature switches Door Insulation Kit - Kit F, • Includes bulk insulation to reseal doors Under Frame Square Gasket Kit- Kit G, • Includes return air and duct air gaskets Pressure Switches &Sensor Kit - Kit H, • Contains high pressures switch, low pressure switch, modulation switch, and 3 (three) temperature switches