Specifications include, but are not limited to: Location - Space shall be located within the city limits of Seguin. Building - Entire agency space shall be contiguous and located on a single floor. Doors and Locks - Except for the main entry, any doors leading to the outside of the building from the leased space shall be metal clad with view slot or peephole. All interior doors shall be minimum 3 wide and solid core. - Doors with locks and that swing outward shall have non-removable hinge pins, metal frames and astragal plate covering the latch. - All exterior doors will be keyed alike not on any master. Provide six (6) exterior door keys each stamped "DO NOT DUPLICATE". Main entrance door shall have a deadbolt entry function lock (ANSI E2151). All other exterior doors shall have a store room function lock (ANSI F86) and a deadbolt entry function lock (ANSI E2151). - All exterior doors, except for the main entry, will be utilized as employee entrances. Tenant shall provide electronic security card swipes. - All interior Offices shall be equipped with individually keyed office function locks (ANSI F82) and master keyed. - All other interior room doors, except the Break Room, shall be equipped with individually keyed store room function locks (ANSI F86) and master keyed. Provide 2 individual keys for each interior lock and a total of 6 master keys. All keys are to be presented to occupying agency. - Closers required on all doors in Client Waiting Room, Telephone/Data Room, rest rooms and doors leading outside the lease space. - Interior office doors will remain open during business hours.