RO FEED PUMP & MOTOR REFURBISH EQUIPMENT- 3 PHASE VERTICAL MOTOR, HP: 500, RPM'S: 3570, VOLTS: 460, MAKE- FRAME: 5012VP, EMERSON-US MOTORS MOTOR SCOPE QUANTITY OF 3: PICKUP MOTOR FROM LOCATION: J ROBERT DEAN WTP, 35400 SW 192 AVE HOMESTEAD, FL 33034 - PERFORM A VISUAL INSPECTION OF MOTOR COMPONENTS FOR THE PRESENCE OF CONTAMINATION BY DUST, DIRT, MOISTURE, OIL, AND OTHER FOREIGN MATTER. DISASSEMBLE MOTOR AND ATTEMPT TO DETERMINE THE ORIGIN OF FAILURE, SUCH AS LEAKING SEALS, LOOSE MECHANICAL COMPONENTS OR ANY UNUSUAL CONDITIONS PRIOR TO THE START OF CLEANING. NOTE ALL ABNORMAL CONDITIONS ON THE STATOR, ROTOR, AND WINDINGS. CAREFULLY EXAMINE THE INTERIOR OF THE MOTOR FOR LOOSE OBJECTS SUCH AS, NUTS AND BOLTS. REMOVE ALL SUCH ITEMS. INSPECT ALL ELECTRICAL CONNECTIONS FOR TIGHTNESS. CHECK ALL WEDGES, BANDS, AND SOLDERED CONNECTIONS AND CORRECT ANY MINOR DEFICIENCIES. CHECK FOR EVIDENCE OF OVERHEATING, BOTH GENERAL AND LOCALIZED. IDENTIFY ANY MECHANICAL DEFICIENCIES. RECORD ALL FINDINGS, INCLUDING THE TYPES OF CONTAMINANTS (OIL, WATER, CARBON, DIRT, ETC.) FOUND. - INSPECT ANY MOTOR ACCESSORIES, SUCH AS TEMPERATURE SENSOR, SPACE HEATER, CAPACITOR, TACHOMETER, ELECTROMAGNETIC BRAKE, OR SPACE HEATER, AND THE ASSOCIATED INTERNAL WIRING. TEST ACCESSORY OPERATION AND SUBMIT A FINDING REPORT WITH RECOMMENDATIONS FOR REPAIR OR RENEWAL. - CLEAN & DIMENSIONALLY CHECK ALL BEARINGS, BEARING JOURNALS, HOUSING, SEAL SURFACE, CONTROL CABLE, ETC…, AS APPLICABLE, DOCUMENT FINDING. - PERFORM CORE LOSS TEST OF STATOR AND ROTOR LAMINATIONS IN ORDER TO DETERMINE IF CORE LAMINATIONS MAINTAIN THE ORIGINAL DESIGN EFFICIENCY