he apparatus, fully equipped and in-service, SHALL NOT EXCEED the following dimensional requirements: Overall Length (OAL): 342 inches (28' 6") Maximum. Overall Height (OAH): 120 inches (10' 0") Maximum. Overall Width (OAW): 100 inches (8' 4") Maximum. 1.2 NFPA and Federal Compliance The completed apparatus SHALL be designed, manufactured, and tested in full compliance with the latest edition of NFPA 1901, Standard for Automotive Fire Apparatus, specifically the requirements for a Water Tanker/Tender. 1.3 Weight and Stability Requirements The manufacturer MUST comply with the following: 1. 2. 3. Maximum Load: The completed apparatus, when loaded to its estimated in-service weight (including 3,000 gallons of water and NFPA minimum payload), SHALL NOT EXCEED the stated GVWR of the chassis (64,000 lbs) or the specified GAWR for either axle. Weight Analysis: A certified computer weight analysis SHALL be submitted, detailing all major components, the distribution of the NFPA minimum payload, and the resulting weight impact on the front and rear axles. Center-of-Gravity (COG): A certified COG calculation SHALL be submitted, confirming the apparatus meets all NFPA stability and tilt-angle requirements