• Minimum wall thickness 4” (102 mm) • Factory-installed insulation is a minimum of 1” (25 mm) thick. • Sound Transmission Rating (STC) 38-51minimum • Base track must securely attach to the base building floor to prevent wall movement once in place. • Wall system includes frames, insulation, doors, and finished wall panels. • Modular, plug-in connections allow for easy installation and modifications. • Electrical systems include zone boxes, modular splitters, extender cables, and pre-wired device boxes. Two electrical outlets and two data connections will be provided for each wall of the modular office to allow for flexibility in workspace layout. Office Dimensions o Office – Main Floor 5 Offices at 9’ 6” wide by 12’ deep by 9’ high o Office – Main Floor 1 Office at 9’ 6” wide by 15’ 8” deep by 9’ high o Office – Lower Level 1 Office at 15’ 3” wide by 9’ deep by 9’ 3” high • Fire Resistance: o Surface-Burning Characteristics: Finishing materials shall be tested in accordance with ASTM E84 or NFPA 286. The Integrated Interior Assembly shall be approved for use by a qualified independent testing agency in Type I and Type II Construction. • Note: Warranty, Shipping, and handling will be included in the cost