A more detailed Scope of Work includes, but is not necessarily limited to, the following: 2.1 Install approximately twenty (20) linear feet of 6-inch PVC C900 waterline. 2.2 Installation method: Horizontal Directional Drilling (HDD) or Bore and Jack. Base Bid: Install 6-inch PVC C900 inside a ½” thick, minimum 10-inch steel casing pipe with casing spacers and end seals. Alternate 1: Install 6-inch HDPE pipe without casing, provided that the wall seal system is rated and approved by Brunswick County. 2.3 Alignment is beneath an existing building wall into a below-grade dry well at approximately six (6) feet depth. 2.4 Core through an existing 12-inch-thick concrete foundation wall. 2.5 Seal penetration using LINK-SEAL® Modular Seal, Pipetite® Wall Boot, or approved equal.