PERFORMANCE REQUIREMENTS A. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Flame-Spread Index: 75 or less. 2. Smoke-Developed Index: 450 or less. 3. Fire Rating: Class B B. Regulatory Requirements: Comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines for Buildings and Facilities and ICC A117.1 for toilet compartments designated as accessible. 2.2 PHENOLIC-CORE TOILET COMPARMENTS A. Basis of Design Manufacturer: ASI Accurate Partitions; 160 Tower Drive, Burr Ridge, IL 60527; Tel. (706) 442-6800; info@asi-accuratepartitions.com B. Toilet-Enclosure Style: Floor anchored / overhead braced. 1. Compartment Depth and Width: As indicated on drawings 2. Door Width: As indicated on the Drawings 3. Height Above Floor: 12 inches (305 mm) unless otherwise noted. C. Urinal-Screen Style: Wall hung. 1. Screen Panel Size: 18 inches (457 mm) wide by 36 inches (915 mm) high. 2. Height Above Floor: 18 inches (457 mm). D. Door, Panel, Screen, and Pilaster Construction: Solid phenolic-core panel material with melamine facing on both sides fused to substrate during panel manufacture (not separately laminated), and with eased and polished edges and no-sightline system. Provide minimum 3/4 inch (19 mm) thick doors and pilasters and minimum 1/2 inch (13 mm) thick panels. E. Pilaster Shoes and Sleeves (Caps): Formed from stainless-steel sheet, not less than 0.031 inch (0.79 mm) nominal thickness and 3 inches (76 mm) high, finished to match hardware. F. Brackets (Fittings): 1. Stirrup Type: Ear or U-brackets, stainless steel. G. Phenolic-Panel Finish: 1. Color and Pattern: Burnt Strand 5107 with manufacturer's standard black color core. H. Fire Rated Material: Class B 2.3 HARDWARE AND ACCESSORIES A. Hardware and Accessories: Manufacturer's standard operating hardware and accessories. 1. Material: Stainless steel. 2. Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible. B. Hardware and Accessories: Manufacturer's heavy-duty stainless steel operating hardware and accessories. 1. Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible. C. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with anti-grip profile and in manufacturer's standard finish. D. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel, finished to match the items they are securing, with theft-resistant-type heads. Provide sex-type bolts for throughbolt applications. For concealed anchors, use stainless-steel, hot-dip galvanized-steel, or other rustresistant, protective-coated steel compatible with related materials.