1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. BEFORE BEGINNING WORK AT THE SITE AND THROUGHOUT THE COURSE OF WORK, INSPECT AND VERIFY THE LOCATION AND CONDITION OF EVERY ITEM AFFECTED BY THE WORK UNDER THIS CONTRACT AND REPORT DISCREPANCIES TO THE ARCHITECT BEFORE BEGINNING WORK RELATED TO THAT BEING INSPECTED. BEFORE BEGINNING WORK AT THE SITE, INSPECT THE EXISTING BUILDING AND DETERMINE THE EXTENT OF EXISTING FINISHES, SPECIALTIES, EQUIPMENT, AND OTHER ITEMS WHICH MUST BE REMOVED AND REINSTALLED IN ORDER TO PERFORM THE WORK UNDER THIS CONTRACT. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPLE AREAS WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT. INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS NOT SHOWN ON THE ARCHITECTURAL DRAWINGS DUE TO CHANGES AFFECTING EXISTING MECHANICAL, ELECTRICAL, PLUMBING, AND OTHER SYSTEMS. SUCH INCIDENTAL WORK IS ALSO PART OF THIS CONTRACT. INSPECT THOSE AREAS AND ASCERTAIN WORK NEEDED AND DO THAT WORK IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS AT NO ADDITIONAL COST. PROTECT EXISTING FINISHES TO REMAIN FROM DAMAGE. REPAIR, PATCH, OR REFINISH AS APPLICABLE TO MATCH ADJACENT EXISTING FINISHES, THOSE FINISHES DAMAGED OR NEWLY EXPOSED DURING PERFORMANCE OF THE WORK UNDER THIS CONTRACT. WHERE MATCH EXISTING IS INDICATED, NEW CONSTRUCTION OR FINISHES, SHALL MATCH THE EXISTING IN EVERY PARTICULAR. WHERE PERMANENT REMOVAL OF EXISTING CASEWORK, DOORS AND FRAMES, EQUIPMENT, OR FURNISHINGS IS REQUIRED AND PREVIOUSLY CONCEALED SURFACES ARE TO REMAIN EXPOSED, PATCH PREVIOUSLY CONCEALED SURFACES TO MATCH ADJACENT EXPOSED SURFACES. WHERE SUCH SURFACES ARE SCHEDULED TO RECEIVE NEW FINISHES, PREPARE THE SURFACES TO RECEIVE THE NEW FINISHES. WHERE CUTTING OF EXISTING SURFACES OR REMOVAL OF EXISTING SURFACES IS REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT, AND NEW FINISH IS NOT INDICATED, FILL RESULTING OPENINGS AND PATCH THE SURFACE AFTER DOING THE WORK AND FINISH TO MATCH ADJACENT EXISTING SURFACES. REFER TO NEW WORK PLANS TO COORDINATE EXTENT OF DEMOLITION REQUIRED. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION DRAWINGS FOR ADDITIONAL DEMOLITION REQUIRED. CONTRACTOR TO NOTIFY ARCHITECT IMMEDIATELY UPON DISCOVERY OF CONFLICT OR DISCREPANCY WITH ITEMS INDICATED TO BE REMOVED. WHERE NOT SPECIFICALLY NOTED, CONTRACTOR SHALL MODIFY EXISTING FLOORING AND CEILING CONSTRUCTION TO REMAIN AS REQUIRED TO ABUT NEW CONSTRUCTION AND MATCH ADJACENT EXISTING CONDITIONS. COORDINATE SLAB REMOVAL AND REPLACEMENT WITH PLUMBING AND ELECTRICAL UNDERGROUND AND IN-SLAB WORK. WHERE AN ITEM IS SHOWN TO BE REMOVED OR DEMO'ED ALL MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS SHALL BE REMOVED WITH IT U.N.O. ELECTRICAL WIRING AND CONDUIT SHALL BE REMOVED BACK TO NEAREST JUNCTION BOX TO REMAIN. DUCTS AND TERMINALS SHOULD BE REMOVED AS FAR AS NECESSARY FOR NEW DISTRIBUTION SYSTEM OR COMPONENTS TO TIE INTO, OR CAP WITHIN CONCEALED SPACE. PRIOR TO COMMENCEMENT OF DEMOLITION, COORDINATE REMOVAL OF DORMITORY FURNITURE AND EQUIPMENT WITH OWNER