Cabin #5, 15 Doswell Lane 1. Pressure wash and repoint exterior brick and apply a siloxane-based water repellant. Replace crown with tile extension and crown seal. 2. Scrape and re-caulk flashing. 3. Replace cap with stainless steel cap with expandable metal spark arrestors. Cabin 6, 34 Lathan Circle 1. Reline fireplace flue with 12” x 20” stainless steel double wall liner and chimney liner insulation. 2. Pressure wash and repoint exterior brick and apply a siloxane-based water repellant. Replace crown with tile extension and crown seal. 3. Scrape and re-caulk flashing. 4. Replace cap with 13” x 13” stainless steel cap with expandable metal spark arrestors. 5. Deglaze, parge, and base seal throat. 6. Parge lintel. 7. Demo, re-lay, and repoint firebox. Cabin 7, 42 Lathan Circle 1. Reline fireplace flue with 12” x 20” stainless steel double wall liner and chimney liner insulation. 2. Pressure wash and repoint exterior brick and apply a siloxane-based water repellant. Replace crown with tile extension and crown seal. 3. Scrape and re-caulk flashing. 4. Replace cap with 13” x 13” stainless steel cap with expandable metal spark arrestors. 5. Deglaze, parge, and base seal throat. 6. Parge lintel. 7. Demo, re-lay, and repoint firebox. Cabin 8, 50 Latham Circle 1. Reline fireplace flue with 12” x 20” stainless steel double wall liner and chimney liner insulation. 2. Pressure wash and repoint exterior brick and apply a siloxane-based water repellant. Replace crown with tile extension and crown seal. 3. Scrape and re-caulk flashing. 4. Replace cap with 13” x 13” stainless steel cap with expandable metal spark arrestors. 5. Deglaze, parge, and base seal throat. 6. Parge lintel. 7. Demo, re-lay, and repoint firebox.