Elevator Operation Upgrade Requirements New automatic self-leveling, which will bring the elevator car level with the flooring landings + ¼” regardless of direction of travel. New Special Emergency Service operation in compliance with the latest applicable revision of the ASME/ANSI A17.1 Code. Special Emergency Service Phase I to return the elevator non-stop to a designated floor shall be initiated by an elevator smoke detector system. The smoke detector system shall be furnished by the Airport and the elevator vendor will provide contacts on the elevator controller to receive signals from the smoke detector system. New independent service. When the switch is actuated, it shall cancel previously registered car calls, disconnect the elevator from the hall buttons, and allow operation from the car buttons only. Door operation shall occur only after actuation of the “Door Close” button. New inspection operation, which will have an enabling keyswtich in the car operating panel to permit operation of the elevator from on top of the car and to make car and hall buttons inoperative. Hoistway Access Switch will be provided in the car operating panel to render all car and hall buttons inoperative and to permit operation of the elevator by means of an access keyswitch adjacent to the hoistway entrance at the access landing. Elevator Machine Room Upgrade Requirements The existing power supply is 208V 60HZ and will be retained with the new equipment.