Contractor shall perform the following: Perform pre-test of Duress/Panic System Individual wireless and hardwired duress inputs. Perform walk test of perimeter doors and Emergency stair exit doors. Perform Second walk test to ensure functionality after completion of door contact installation at all locations. Replace or install all door contact, recessed or surface mount. Access perimeter doors, Emergency stair exit doors. Replace existing Main REX Controllers to new current Main Alarm Controller model AC-2700. Replace duress/panic button hardwired input with new Rutherford Controls International (RCI) Rocker Switch. Replace duress/panic wireless switch- program device digital serial number and enroll to the wireless receiver, remove, and replace with new Inovonics Echostream unit, and wireless duress/panic pendant buttons. Replace Echostream Receiver: (Transmits contact closures in conjunction with Wireless Transmitters to ensure connectivity to the access control system). ONE TIME - PURCHASE and installation of PINNACLE Sielox HARDWARE Equipment Contractor shall provide the following: Replacement and installation of the Badge Printer. Replacement and installation of the Pinnacle Server. Provide Fargo printer ribbon. ONE-TIME PURCHASE license reinstatement fee Contractor shall include the following: License reinstatement Fee for Lapsed Pinnacle Professional Support Agreement. ONE-TIME ELEVATOR CARD READER REPROGRAMMING Contractor shall include the following: Contractor shall reprogram elevator card readers and access schedules in Pinnacle. ONE-TIME PURCHASE and installation OF PINNACLE SIELOX SOFTWARE Contractor shall include the following: Pinnacle Software license to support one (1) server and one (1) server workstation. Pinnacle Software license(s) for two (2) client workstations. Pinnacle Badging License Software. Pinnacle Multi Server Hardware License.