2.01.1 Pre-engineered Building Specifications • Building Code IBC 2018 with Risk Category: II • Withstand wind speeds up to 160 MPH • Drift/Deflection: Standard Exposure: “B” – Surface Roughness B. Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. • Additional loads: as prescribed by 2018 IBC and/or ASCE-7 • Building Enclosure type: Open – Note: The structure shall be designed for wind loads for the worstcase scenario: open, partially enclosed and/or enclosed – it is the intent of the City to enclose structure at a future date. 2.01.2 Building Description: • Pre-Engineered Building Specifications o Building Code IBC 2018 with Risk Category: II o Withstand wind speeds up to 160 MPH o Drift/Deflection: Standard • Exposure: “B” - Surface Roughness B. Urban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. o Additional loads: as prescribed by 2018 IBC and/or ASCE-7 o Building Enclosure type: Open – Note: The structure shall be designed for wind loads for the worst-case scenario: open, partially enclosed and/or enclosed – it is the intent of the City to enclose structure at a future date. • Building description: o Galvalume Plus exposed fasteners, 26-gauge roof with 1:12 pitch – No skylight panels (Owner to select colors) o No walls – Note: Building designed to accept wall girts and panels in the future - 26-gauge standard color exposed fastener wall and bay-end roll up doors – plan set shall provide future wall and door system design. (Owner to select colors) o No Insulation (Roof) o Standard eave trim o See attached renderings • Additive Alternate – Top Half of Rear and Side Wall Enclosure o 26-gauge standard color exposed fastener wall (Owner to select colors) o Girts per design drawings o No doors, windows or building penetrations