1.0 METAL POLE BUILDING PAVILION SPECIFICATIONS • Proposed building location: 800 Crosby Rd. Front Royal, VA 22630 • Building size: 16 ’W x 24‘L x 12‘H Open Pavilion • Posts: 4” x 6” 0.60 CCA pressure treated • Trusses: 4/12 pitch, 48” o.c. • Skirt-board: None • Headers/ Truss Carriers: Double 2x10 • Roof Purlins & Wall Girts: 2”x4”, 2’ o.c., horizontal • Roof And Sidewall Covering: 29 gauge painted steel, 40-year paint warranty • Fasteners: All metal is attached with Color matched screws. All framing secured with 3” x .131 nails. • Ventilation/Overhangs: o 12” eaves with vented soffit o Flush gables o Vented Ridge • Doors: ( N/A ) 3068 6-panel entry door w/ composite jamb • (N/A ) ‘W x ‘H raised panel, insulated, overhead door(s) • Windows: n/a • Lean-to/Porch Roof: n/a • Miscellaneous: o Construction Labor Included o Header stiffeners installed at bottom of headers. o Bird blocking installed at eaves & gable. o Scrap & Construction Debris to be placed in dumpster on site, provided by the Town. • Required Options: o The contractor shall obtain permits, using customer supplied plat survey. o The contractor shall provide Engineered Sealed Construction Plans as required by Warren County for permitting. o Work hours will be Monday thru Friday 7am to 3:30pm no work on Weekends or holidays.