Reno County is requesting bids for construction of a 60’ x 80’ x 16’ (Roof Slope 12:1) metal building placed upon a 70’ x 90’ concrete slab. This building will have a total of (8) Garage doors w/ automatic openers, (6) of them 10ft wide by 12ft tall, the remaining (2) 12ft wide by 14ft tall with (2) 36”x84” walkthrough doors. Approximately 265ft of trenching for buried electrical coming from exisiting building on property. Installation of Breaker Panel and running circuits for garage door openers and additional receptacles Approximately 40ft of trenching for sewer line to connect into main sewer line for half bathoom. Roof Sheeting - 26GA DuraRib Long Span Screw Down Panels w/ Gutters and downspouts Garber Surveying Service has been employed to do the permitting for this project. This property located in a flood plain. The location for the concrete slab will require crushed concrete to be brought in for filling purposes to get the finish slab height elevation a minimum of 12” above flood plain elevation. 90’x14’ of slab – 8” conrete on 12” centers to create bay w/ 12ft garage doors 90’x56’ of slab – 6” concrete on 12” centers remainder of building Min 3kpsi for footing and 4kpsi on grade. Trowel finish interior – light broom exterior Include sawcutting of all control joints Provide piping for sewer and tie into exisiting No Frame Reduction is allowed. Concrete and building must be engineered Site elevation survey and drawings avilable upon request.