3.1 General Requirements • Provide and install all access control system components according to project specifications. • Ensure installation of all equipment follows manufacturer guidelines. • Comply with all applicable building codes, safety standards, and organizationspecific requirements. • Label all components and cabling in accordance with industry or organizationspecific standards. • Collaborate closely with IT and Facilities Management staff during implementation. 3.2 System Configuration & Programming • Install and configure access control management software and licensing on a server provided by the organization. • Migrate and rebuild the user database from the existing access control system. • Install client software on designated workstations within the organization. • Conduct full system commissioning, functional testing, and provide training for system users. 3.3 Hardware Installation Breakdown A. Office Building – 27 Access Points • Control Equipment Installation: o Install access control panels and power supplies in designated equipment rooms. • New Door Installations (15): o Install card readers, electrified locking hardware, exit devices (REX), and door contact sensors. • Existing Door Integrations (11): o Reuse existing electrified hardware while installing new readers, motion sensors, and contacts...