FRAME RAILS: COMPLIES ____YES NO____ Type Sealed Dual C Channel or Single Treatment Minimum heat treated,110,000 PSI Specify Heat treat _________ RBM: Minimum 3,000,000 Specify RBM _______ Height: Minimum 10 ½ dual or 12” Maximum (single) Specify Height ______ Thickness: Minimum 3/8”each on dual or 1/2” on single Specify Thickness ______ Cross Members: Heavy duty, steel Frame extensions Length to be determined at build meeting (For FEPTO) Paint: Gloss Black WHEELBASE: COMPLIES __YES NO____ B B C: 114” minimum B B C Measurement: __________ B C A: 136” minimum 144” maximum B C A Measurement: __________ Wheelbase: 230” minimum WB Measurement: __________ Cab to End of Frame: 210” minimum Cab to End of Frame Measurement: __________ Note: Final measurements to be determined at scheduled prebuild meeting. FRONT BUMPER: COMPLIES ____YES NO____ Steel, full width of vehicle with tow hook(s). Minimum thickness 3/8” Specify Thickness ____________ Shall have a minimum of 16” spacing between the back of bumper and front of radiator to accommodate a FEPTO mounted hydraulic pump. Note: Final spacing to be determined at scheduled prebuild meeting. CAB: COMPLIES ___YES NO___ Interior: Inside dimensions: 69” minimum (inside door panel to inside door panel at widest point). Specify Inside Dimension ________________________________ Back of Cab to Windshield at widest point 51” Minimum Specify Cab to Windshield Measurement _______