1. Coriolis Mass Flow Meter, 600 grams per hour full scale o Temperature range: 1 ℃ to 70 ℃ o Max pressure of 1500 PSIA o ¼” compression fittings o RS-232 serial and 0-5 Vdc analog 2. Differential Pressure Meters for Water o Calibrated for 10 bar differential pressure o Max pressure 20 bar differential pressure o Anti-corrosive 316L and FFKM o High-temperature specification for up to 100 ℃ o ¼” compression fittings o RS-232 serial and 0-5 Vdc analog 3. Gauge Pressure Meters for Water o Calibrated for 10 bar Gauge o 316L and FFKM o High-temperature specifications for up to 100 ℃ o ¼” compression fittings o RS-232 serial and 0-5 Vdc analog 4. Software for recording pressures, temperatures, and flow rates 5. Communications cables, power supplies, and relevant breakout boxes to enable all six sensors to communicate with a laptop through one USB cable or DB9.