• Install the Axis P3267-LVE cameras on the building as indicated. • Run CAT6 cable between the county switches and the installed Axis cameras. • Install the purchased Trove 2 enclosure in the site storage room. • Install the purchased LNL-X2220 and Altronix power supply in the mounted Trove 2 enclosure. • Install the purchased HID Signo 40 reader near the door frame indicated. • Install the purchased HID Signo 40 reader next to the intrusion panel keypad. • Install the GRI surface mounted double pole/double throw door contact at the reader door. • Install the Bosch DS160 request to exit in the hallway near the card reader door. • Install the Von Duprin 6210 electric strike on the card reader door frame. • Wire the Altronix power supply to power the LNL-X2220 reader board. • Install any surface mounted conduit to conceal wires in the building. Conduit is needed only where wires would otherwise be visible in normal building use (i.e. conduit is not needed if wire is being run through the ceiling) • Wire the installed door contacts, electric strikes, REXs, and card readers to the Lenel access panel. o The door contact will be wired to the intrusion panel and the card access system. • Program the Signo 40 card reader to arm the existing Bosch intrusion panel. • Program the 2 installed card readers into the County’s OnGuard 8.2 card access software.