Sitework/Landscaping: Sitework is limited to restoring lawn to original condition including repair of ruts and damage caused by construction activities. Landscaping-Contractor shall only remove plantings and landscaping features if required as part of the electrical upgrades. Contractor shall restore all landscaping beds to pre-construction condition and sod/seed any disturbed grass areas. Electrical: Coordinate all work with CNB Corporate Construction, TPWA, and City of Tahlequah Code Compliance. Demo existing panel feeder and associated components. Carefully trench all new circuits required for installation of electrical components to ensure minimal damage to adjacent utilities, landscaping, and hardscapes. Coordinate with Owner’s facilities staff prior to trenching to locate irrigation heads and lines. Contractor shall repair/replace any damaged utilities. Carefully sawcut all sidewalk crossings per City of Tahlequah requirements. Provide and install the following electrical systems, complete in place, in accordance with plans and specifications: Demo existing service entrance conductors and upgrade to calculated size as required by NEC. Underground branch circuitry within conduit to all pedestals and receptacles as required. Provide and install the following fixtures only: RV 50AMP Pedestals-2 each (CKT 17,19,20,21) P1 Recept Pedestal NW (CKT 12) P1 Recept Pedestal SW (CKT 14) P1 Recept Pedestal SE (CKT 20) P1 Recept Pedestal NE (CKT 24) (RV pedestal branch circuitry and overcurrent protection to be rated at 90 amps, P1 receptacles branch circuitry and overcurrent protection to be rated at 20 amps.) Include two (2) additional 2” PVC sleeves at all sidewalk crossings.