Specifications include, but are not limited to: • 8441 Spinoza Detroit MI. 48239 (Outdoor) o 30 lane sand backstop with 30 actuating targets system o Plywood canopy with wood and metal support beams o Round count: Approximately 870,000 annually o Provide routine range maintenance/Cleaning o Lead/brass reclamation, transport and recycling o Berm Excavation: Excavate soil from the operating backstop berms and apron area or shot fall zone. Excavate soil from the backstop berms. o Lead Reclamation: Separate lead bullets/bullet/shot fragments from the excavated soils. Separate sand material from bullet and bullet fragments using the EPArequired two-step process. o Recover and Recycling: of lead and or brass. o Maintenance/upkeep/replace 30 actuating targets o Maintenance and upkeep must take into account standing water that accumulates from Rouge River water shed during heavy rain • 4700 Fort St Detroit Ml 48209 (Indoor) o 6 lane rubber backstop with 6 lane track targeting system o Lead/brass reclamation and recycling o Berm Excavation :bullet/bullet fragment removal for transport/recycling o Replace granular rubber back onto the trap and groomed to a uniform depth across the trap