1. Demo exiting security camera system and all components to exclude cabling and monitors. 2. Furnish, install, and configure a server with a minimum of 16 TB available storage. 3. Furnish and install CAT6 cabling to all new cameras (install conduit if necessary to get cables to locations). Terminate both ends of cables with RJ45s. Test and label cables. 4. Furnish, install, configure, and adjust one (1) outdoor NDAA compliant varifocal camera with distance viewing 5. Furnish, install, configure, and adjust eight (8) indoor NDAA compliant mini-dome cameras 6. Furnish, install, configure, and adjust one (1) outdoor NDAA compliant 180-degree camera 7. Furnish, install, configure, and adjust four (4) outdoor NDAA compliant 360-degree cameras 8. Furnish, install, configure, and adjust one (1) indoor NDAA compliant dome camera for Police interview room with external microphone and input trigger. 9. Furnish and install new low-voltage switch with indicator light in booking room for officers to initiate recording.