PACKAGE #1 415–501 E Puget Avenue a. Domestic Water: • Existing System o Pressure Zone 3A. o 6-inch ACP water main within E Puget Avenue. o 6-inch ACP water main within N 4th Street. o 2-inch unknown material water main stub towards project site (Do Not Use, Substandard Main). o 2-inch unknown material water main stub towards project site (Do Not Use, Substandard Main). o City map shows 2-inch water tap to project site. o City map shows three 1.5-inch water taps to project site. o City map shows 1-inch water tap to project site. o Field verification will be necessary to determine if services are still active. • Other Stipulations o When multiple distribution mains in the same pressure zone are adjacent to a development, all service connections shall be taken from the largest diameter main or as approved by City Water Services Department through the Technical Appeal process. o Per Chapter Code 37-48 and 28-29 do not allow water or sewer services to cross through property lines. b. Sewer • Existing System o 8-inch VCP sewer main within E Puget Avenue. o 8-inch VCP sewer main within N 4th Street. o City map shows four 4-inch sewer taps to project site (Do Not Use). Commercial projects require 6-inch sewer tap minimum. • Other Stipulations o Phoenix City Code 37-48 and 28-29 do not allow water or sewer services to cross through property lines. General Stipulation for Package #1 parcels o Per City Code Chapter 37-33, all public streets bounding (along property frontage) and within a proposed development must have public water mains within them, if none exists, developer must install. PACKAGE #2 8930 N 3rd Street a. Domestic Water • Existing System o Pressure Zone 3A. o 2-inch Galvanized water main within alley to the west of project site (Do Not Use, Substandard Main). o 6-inch ACP water main within N 3rd Street. o City map shows no water taps to project site. • Other Stipulations o When multiple distribution mains in the same pressure zone are adjacent to a development, all service connections shall be taken from the largest diameter main or as approved by WSD through the Technical Appeal process. o Phoenix City Code 37-48 and 28-29 do not allow water or b. Sewer • Existing System o 8-inch VCP sewer main within alley to the west of project site. o City map shows no sewer taps to project site. Commercial projects require 6-inch sewer tap minimum. • Other Stipulations o Phoenix City Code 37-48 and 28-29 do not allow water or sewer services to cross through property lines. General Stipulation for Package #2 parcel o Per City Code Chapter 37-33, all public streets bounding (along property frontage) and within a proposed development must have public water mains within them, if none exists, developer must install. o Detailed water/sewer stipulations will be provided at preapplication/pre-liminary site plan review stage that may include additional infrastructure improvement requirements.