A. Specifications of existing a. 4 th floor i. 99 three lamp fixtures 1. 4x8 troffers 2. 120VAC 3. Ballast driven T8’s ii. 5 can lights 1. 6 inch round 2. 120VAC b. North stairwell upper portion i. 3 can lights 1. 6 inch round 2. 120VAC ii. 4 two lamp fixtures 1. 1x4 strip 2. 120VAC 3. Ballast driven T12’s c. North stairwell lower section i. 1 round florescent 1. 120VAC 2. Ballast driven ii. 1 three lamp fixtures 1. 4x8 troffer 2. 120VAC 3. Ballast driven T8’s iii. 1 two lamp fixture 1. 120VAC 2. Surface mount 1x4 3. Ballast driven T8’s d. South stairwell i. 6 round florescent 1. 120VAC 2. Ballast driven ii. 2 can lights 1. 6 inch round 2. 120VAC iii. 1 two lamp u light 1. 120VAC 2. Ballast driven B. Specifications of new a. 4 th floor i. 101 New LED fixtures 1. Suitable for line voltage 100-277VAC 2. Flat panel 3. Fit standard 2x4 T grid ceiling 4. Lumens output per fixture 5,600 5. Watts 45 6. Color: 4,000K ii. 1 New LED fixtures 1. Suitable for line voltage 100-277VAC 2. Flat panel 3. Fit standard 2x2 T grid ceiling 4. Lumens output per fixture 4,200 5. Watts 35 6. Color: 4,000K iii. 1 new LED can light 1. 8 inch round 2. Suitable for line voltage 100-277VAC 3. Recessed downlight 4. Lumens output per fixture 2,700 5. Watts 29 6. Color 4,000K b. North stairwell upper i. 4 New LED fixtures 1. Suitable for line voltage 100-277VAC 2. Flat panel 3. Fit standard 2x4 T grid ceiling 4. Lumens output per fixture 5,600 5. Watts 45 6. Color: 4,000K ii. 4 new LED fixtures 1. Suitable for line voltage 100-277VAC 2. 4 foot strip fixture 3. Lumens output per fixture 3,900 4. Watts 28 5. Color: 4,000K c. North stairwell lower i. 1 New LED fixtures 1. Suitable for line voltage 100-277VAC 2. Flat panel 3. Fit standard 2x4 T grid ceiling 4. Lumens output per fixture 5,600 5. Watts 45 6. Color: 4,000K