Single Mode Dark Fiber Service Requirements - 3.3.9.1.1 The Single Mode Dark Fiber Service shall be One (1) Pair (2 fibers) of Single Mode Fiber that complies with ITU-T G652 specifications from the Part III end-point to the ICN CPOP. 3.3.9.1.2 The End-to-End distance of the fiber, from the Part III End Point location to the ICN CPOP location, must be less than 23.2 miles (37.1 km). 3.3.9.1.3 The End-to-End span loss of the fiber, from the Part III End Point Location to the ICN CPOP location, must be less than/equal to .39dbm/km at the 1310nm wavelength and less than/equal to .25dbm/km at the 1550nm wavelength. 3.3.9.1.4 Telecommunication Service Vendor fiber cable shall be installed in compliance with current Telecommunications Industry Standards/Practices and all applicable local building and electrical codes. 3.3.9.1.5 Telecommunication Service Vendor outside plant fiber cable must be terminated in a Telecom Standard Fiber Termination Panel (FTP), Wall Mount Type with FC/PC or SC termination connectors (location of the wall mount FTP in FOTS room to be assigned by ICN). The FC bulkhead connector in the Vendor wall mount FTP will be considered the Demarcation Point of the Single Mode Dark Fiber Service...