1. Standard Test Method for Determining Air Leakage Rate by Fan Pressurization – Blower Door a. Spec Section: Not in Specifications – conduct per code and in coordination with Cx Agent and Project Team. b. Testing Required: ASTM E 779 2. Aluminum Framed Entrances and Storefronts a. Spec Section: 08 41 13 b. Testing Required: ASTM E 783/AAMA 5033, ASTM E 1105/AAMA 5033, AAMA 501.2 3. Glazed Aluminum Curtain Wall a. Spec Section: 08 44 13 b. Testing Required: ASTM E 783/AAMA 5033, ASTM E 1105/AAMA 5033, AAMA 501.2 4. Fiberglass Sandwich Panel Accessories a. Spec Section: 08 45 23 b. Testing Required: ASTM E 1105, AAMA 501.2 5. Unit Skylights a. Spec Section: 08 62 00 b. Testing Required: Water Leaks per AAMA 501.2 - Total Area of Each Skylight 6. Indoor Air Quality Testing a. Spec Section: 01 81 19 – Section 3.03.C.3 b. Testing Required: Air Quality – See Spec. c. NOTE: the “flush out” requirements are not being pursued, hence the potential air quality testing proposals sought here. d. NOTE: Break out as “Alternate #1” in the Fee Proposal Form (See Section IX). The owner may elect to award the testing services to a given firm with or without the Add Alternate testing. e. NOTE: If the responding firm is not capable of providing the Air Quality testing, they should simply mark “N/A” on the bid proposal form. Not providing the air quality testing alternate does not preclude a firm from submitting a proposal and potentially being awarded the other testing.