Specifications include, but are not limited to: REPAIR SHALLOW DEPTH AREAS OF SPALLED OR DELAMINATED FLOOR CONCRETE WITH OR WITHOUT EXPOSED REINFORCING STEEL INCLUDING JOINT SEALANT AROUND REPAIR AREA. RESTRIPE REPAIR AREA, IF APPLICABLE. INSTALL NEW WASH POUR OR TOPPING SLAB IN AREAS INDICATED TO HELP FACILITATE DRAINAGE. REPAIR SHALLOW DEPTH AREAS OF VERTICAL / OVERHEAD SPALLED OR DELAMINATED CONCRETE WITH OR WITHOUT EXPOSED REINFORCING STEEL. REPAINT REPAIR AREA, IF APPLICABLE. GROUT AND SEAL FLOOR CRACKS WHERE INDICATED ON PLAN. EPOXY INJECT VERTICAL / OVERHEAD CRACKS WHERE INDICATED ON THE PLANS. REPAIR SHALL INCLUDE REPAINTING OF REPAIR AREA, IF APPLICABLE. CRACKED MASONRY GROUT WILL BE REPLACED WITH NEW MORTAR. REMOVE ALL EXISTING HORIZONTAL FLOOR JOINT SEALANT IN JOINTS OR CRACKS AND INSTALL NEW JOINT SEALANT. REMOVAL AND REPLACEMENT ALSO INCLUDES INTERIOR VERTICAL AND HORIZONTAL JOINTS AROUND COLUMNS, AND VERTICAL JOINTS BETWEEN SPANDRELS AND WALL PANELS.