Specifications include, but are not limited to: A new FEMA storm shelter will be constructed in the Cartersville community. The position of the proposed shelter upon the site has not been set at the time of this report. Based on conversations with Michael Posey, the shelter is likely to be placed along the western portion of the exploration area. Building Construction CMU construction supported by concrete grade beams and a structural slab Finished Floor Elevation Not provided. Assumed to be within 1 to 2 feet of existing grades. Anticipated Maximum Loads Walls: 1 to 2 kips per linear foot (klf) Grading/Slopes No significant site grading or new slopes are anticipated. Below-Grade Structures None Free-Standing Retaining Walls None Graveled Drives/Parking Anticipated traffic volumes for graveled drives/parking design have been assumed, based on our experience with similar projects site conditions. We have assumed a 20-year lifespan. Building Code IBC 2018