Specifications include, but are not limited to: Replacement of twelve (12) existing LRV 12TNO2 HVAC units with twelve (12) LRV 10TMM units or equivalent. Replacement units must directly interface with the Brookville control systems currently installed on the Canal Streetcars and selected vendor must provide onsite maintenance and maintenance training for this system. Specifications for Replacement Units: Capacity Data System net cooling capacity at 35°C (95°F) / 26.6°C (80°F) / 50% (ambient air-dry bulb temperature / inside air dry bulb temperature / inside air inlet relative humidity) • Cooling Capacity (related to the frequency rate) kW: 28/34 • Heating Capacity (electrical or hot water) kW: 0-24 • Refrigerant Type: R-407C • Compressor Type: Scroll; Electrical Data • Power Voltage Range @ 60Hz (AC) V: 208-480 • Control Voltage Range (DC) V: 24-110 • Frequency Rate Hz: 50/60 • Power Consumption, Full Cool (nominal @ 60Hz) kW: 17-20...