Specifications include, but are not limited to: Contractor shall build out a temporary wall around the damages area in order to secure and protect the property of NOCCA. Contractor shall build any support system needed to support the existing damaged wall. Contractor shall remove the existing door frame and transom from the damaged wall. Contractor shall remove the damaged section of the wall and salvage all bricks that are not damaged. Contractor shall rebuild the wall using the salvaged and reclaimed bricks as well as bricks that NOCCA has on site. Contractor shall supply matching bricks if this does not provide enough material to complete the repair. Newly installed bricks shall match the existing bricks. Contractor shall provide and install a new door-welded transom frame approximately 7'0" x 9'4" made out of Galvanized Steel. Jamb depth is approximately 7¼". Wall thickness is approximately 6 ¼". Contractor shall provide and install one pair of fire rated metal doors, each approximately 83” L x 36” W X 2” D. All door hardware shall be provided and installed by the Contractor. Laminated security glass shall be installed in the transom by the Contactor. Contractor shall prime and apply two coats of paint to the door frame, doors, and transom with paint provided by NOCCA to match the existing paint color. Any defects found during the removal and repair of the damaged wall shall not be replaced or repaired without prior approval of NOCCA.