Specifications include, but are not limited to: o Hydrogen Fueling Unit: The unit shall be fully self‐contained and self‐monitoring, capable of producing up to 20 kg per day of SAE J2719 & ISO 14687 fuel cell quality hydrogen. The unit shall be capable of providing hydrogen at 700 bar pressure allowing it to fill a standard hydrogen fuel cell powered automobile. The unit shall be equipped with the proper fueling connector to allow it to refill a standard hydrogen fuel cell powered automobile. The unit shall contain a remotely located Site Control panel with incorporated safety and control functions. The unit shall include a thermal rejection unit that will integrate, or is integrated, into the site control functions. A warranty of at least 12 months from date of start‐up or 18 months from date of shipment, whichever is longer. The unit shall only require electricity and water to operate. The power required and the water purification level required is to be specified by the manufacturer in their bid package and that which is typically available in the United States.